AMIQ-PS2 Server Interface Module Firmware Version 4.0.5.0 Release Notes July 7, 2004 =============================================================================== This document outlines: 1. AMIQ-PS2 server interface module firmware version 2. AMIQ-PS2 server interface module firmware compatibility 3. How to upgrade 4. Enhancements/Fixes/Known Issues =============================================================================== AMIQ-PS2 server interface module firmware version =============================================================================== This release contains the following version: Application Code 4.0.5.0 Boot Code 4.0.2.0 FPGA 2.0.8.0 This version of AMIQ-PS2 firmware uses amiqps2.avt files for upgrade of AMX™ switch products. =============================================================================== AMIQ-PS2 server interface module fimrware compatiblity =============================================================================== This release is compatible with the following firmware: AMX5000 switch All revisions. AMX5010 switch All revisions. AMX5100 user station Basic functionality with all revisions. - Full Japanese and Korean layout support with version 1.1.6.3 or higher only - No Extended Keyboard Support. AMX5110 user station Basic functionality with all revisions. - No Extended Keyboard Support. AMX5120 user station Basic functionality with all revisions. - Extended Keyboard Support with revision 1.3.0.0 or higher only AMWorks® software Version 3.0.3.6 AMIQ-PS2 Version 2.0.0.2 (app) 2.0.0.0 (boot) and higher. This release is compatible with the following hardware: AMIQ-PS2 All hardware revisions for AMIQ-PS2. This release will introduce new features that will only operate with the following revisions: AMX5000 switch From revision 3.1.0.0 AMX5010 switch From revision 3.1.0.0 AMX5100 user station From revision 2.0.0.9 AMX5110 user station From revision 2.0.0.9 AMX5120 user station From revision 2.0.0.9 AMWorks software From revision 5.0.0.22 =============================================================================== How to upgrade the AMIQ-PS2 server interface module =============================================================================== To upgrade the flash in the AMIQ-PS2 server interface module, you will need to copy the file AMIQPS2.avt to a machine running AMWorks software rev 3.0.3.6 or higher (5.0.0.22 recommended). Then follow the instructions in AMWorks software for downloading the new software. 1. Download the file "AMIQPS2.avt" to a drive that is accessible by the machine running AMWorks software. 2. Using the AMWorks software, download the file to all the AMIQ modules that are to be upgraded. This is done by selecting Admin Tools - Software Upgrade, selecting the file "AMIQPS2.avt" and the names of the AMIQ modules to be upgraded, and then click begin upgrade. =============================================================================== ENHANCEMENTS =============================================================================== This release of AMIQ-PS2 server interface module firmware contains the following enhancements: 1. Support for Pinnacle Deko FastActionKeyboard 2. DDC stop condition problem fixed 3. Mouse response time improved =============================================================================== Fixes =============================================================================== This release of AMIQ-PS2 server interface module firmware contains the following fixes: 1. Not Applicable =============================================================================== Known Issues =============================================================================== This release of AMIQ-PS2 server interface module firmware contains the following known issues: 1. Not Applicable