-- Avocent Vendor ACS TRAP MIB OID Tree -- Release 04/18/2007 CYCLADES-ACS-TRAP-MIB DEFINITIONS ::= BEGIN IMPORTS cyclades FROM CYCLADES-MIB cyACSMgmt FROM CYCLADES-ACS-MIB MODULE-IDENTITY,OBJECT-IDENTITY FROM SNMPv2-SMI Gauge,enterprises,TimeTicks,IpAddress,Counter,NetworkAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString,PhysAddress FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215; ---------------------------------------------------------------------- -- ACS Trap Object 2925.4.6 (cyclades.cyACSMgmt.cyAcsTrapObject) -- -- The following objects are implemented only for the generation of -- TRAPs. The objects are sent in traps and are not accessible in -- any other way. ---------------------------------------------------------------------- cyAcsTrapObject OBJECT-IDENTITY STATUS current DESCRIPTION " Define the trap objects " ::= { cyACSMgmt 6 } cyAcsModel OBJECT-IDENTITY STATUS current DESCRIPTION " Define the appliance models " ::= { cyACSMgmt 7 } cyAcs1 OBJECT-IDENTITY STATUS current DESCRIPTION " Define the aplliance model ACS-1 " ::= { cyAcsModel 1 } cyAcs4 OBJECT-IDENTITY STATUS current DESCRIPTION " Define the appliance model ACS-4 " ::= { cyAcsModel 4 } cyAcs8 OBJECT-IDENTITY STATUS current DESCRIPTION " Define the appliance model ACS-8 " ::= { cyAcsModel 8 } cyAcs16 OBJECT-IDENTITY STATUS current DESCRIPTION " Define the appliance model ACS-16 " ::= { cyAcsModel 16 } cyAcs32 OBJECT-IDENTITY STATUS current DESCRIPTION " Define the appliance model ACS-32 " ::= { cyAcsModel 32 } cyAcs48 OBJECT-IDENTITY STATUS current DESCRIPTION " Define the appliance model ACS-48 " ::= { cyAcsModel 48 } cyAcsTrapObjectUserName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current --% AVAILABILITY public DESCRIPTION "This object is sent in a trap to identify the name of the user for which the trap condition occurred." ::= { cyAcsTrapObject 1 } cyAcsTrapObjectTargetUserName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current --% AVAILABILITY public DESCRIPTION "This object is sent in a trap to identify the name of the user for which the trap condition occurred." ::= { cyAcsTrapObject 2 } cyAcsTrapObjectSerialPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify which serial port number the trap condition occurred." --% AVAILABILITY public ::= { cyAcsTrapObject 3 } cyAcsTrapObjectSerialSessionType OBJECT-TYPE SYNTAX INTEGER { cas-ssh(1), cas-telnet(2), cas-rawdata(3), ts(4), dial-in(5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify type of Serial Session." --% AVAILABILITY public ::= { cyAcsTrapObject 4 } cyAcsTrapObjectSerialPortName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the target Device by name - alias of the serial port." --% AVAILABILITY public ::= { cyAcsTrapObject 5 } cyAcsTrapObjectAlertMessage OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current --% AVAILABILITY public DESCRIPTION "This object is sent in a trap to identify the line text where the alert string was detected." ::= { cyAcsTrapObject 6 } cyAcsTrapObjectAlertString OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the alert string that matched in the alert message." --% AVAILABILITY public ::= { cyAcsTrapObject 7} cyAcsTrapObjectPMCount OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current --% AVAILABILITY public DESCRIPTION "This object is sent in a trap to identify number of PDU on the chain" ::= { cyAcsTrapObject 8 } cyAcsTrapObjectPMSocketCount OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current --% AVAILABILITY public DESCRIPTION "This object is sent in a trap to identify number of outlets on the chain" ::= { cyAcsTrapObject 9 } cyAcsTrapObjectPMNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current --% AVAILABILITY public DESCRIPTION "This object is sent in a trap to identify the IPDU # the trap condition occurred on." ::= { cyAcsTrapObject 10 } cyAcsTrapObjectPMSocketNumber OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify outlet number the trap condition occurred on." --% AVAILABILITY public ::= { cyAcsTrapObject 11 } cyAcsTrapObjectPMSocketName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify outlet association with serial port name if there any association or the name stored in the PM." --% AVAILABILITY public ::= { cyAcsTrapObject 12 } cyAcsTrapObjectDaemonName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to indicate the Daemon name that has started/stopped." --% AVAILABILITY public ::= { cyAcsTrapObject 13 } cyAcsTrapObjectPMCurrentValue OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to detected current value of the PM." --% AVAILABILITY public ::= { cyAcsTrapObject 14 } cyAcsTrapFirmwareVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify current Firmware version." --% AVAILABILITY public ::= { cyAcsTrapObject 15 } cyAcsTrapNewFirmwareVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify new Firmware version." --% AVAILABILITY public ::= { cyAcsTrapObject 16 } cyAcsTrapFirmwareUpgradeResult OBJECT-TYPE SYNTAX INTEGER { imageUpgradeSuccess(1), imageUpgradeInternalError(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the firmware upgrade result." --% AVAILABILITY public ::= { cyAcsTrapObject 17 } cyAcsTrapObjectSessionType OBJECT-TYPE SYNTAX INTEGER { ssh(1), telnet(2), webui(3), console(4), modempcmcia(5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify type of Session for access to appliance." --% AVAILABILITY public ::= { cyAcsTrapObject 18 } cyAcsTrapObjectTargetedSerialPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify which port the trap condition occurred." --% AVAILABILITY public ::= { cyAcsTrapObject 19 } cyAcsTrapObjectDataBufferSize OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify current size of global buffer." --% AVAILABILITY public ::= { cyAcsTrapObject 20 } cyAcsTrapObjectProcessID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify which session lost data through SSH or telnet session for the appliance." --% AVAILABILITY public ::= { cyAcsTrapObject 21 } cyAcsTrapObjectAlertIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the alert string that matched in the alert message." --% AVAILABILITY public ::= { cyAcsTrapObject 22} cyAcsTrapObjectPMPhase OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the Phase of the IPDU where the trap occurred." --% AVAILABILITY public ::= { cyAcsTrapObject 23 } cyAcsTrapObjectPMType OBJECT-TYPE SYNTAX INTEGER { cyclades(1), spc(2), serverTech(3) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the vendor of the IPDU where the trap occurred. " --% AVAILABILITY public ::= { cyAcsTrapObject 24 } cyAcsTrapObjectPMId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the ID of the IPDU where the trap occurred." --% AVAILABILITY public ::= { cyAcsTrapObject 25 } cyAcsTrapObjectPMSocketOldName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the old outlet name stored in the PM." --% AVAILABILITY public ::= { cyAcsTrapObject 26 } cyAcsTrapObjectPMIdOld OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the old ID of the IPDU where the trap occurred." --% AVAILABILITY public ::= { cyAcsTrapObject 27 } cyAcsTrapObjectPMElementType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the Element Type of the PDU where the trap occurred." --% AVAILABILITY public ::= { cyAcsTrapObject 28 } cyAcsTrapObjectPMElementName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is sent in a trap to identify the Element of the PDU where the trap occurred." --% AVAILABILITY public ::= { cyAcsTrapObject 29 } -------------------------------------------------------------------------------- -- Enterprise Traps -- ACS models: -- ACS1: 2925.4.7.1 (cyclades.cyACSMgmt.cyAcsModel.ACS1) -- ACS4: 2925.4.7.4 (cyclades.cyACSMgmt.cyAcsModel.ACS4) -- ACS8: 2925.4.7.8 (cyclades.cyACSMgmt.cyAcsModel.ACS8) -- ACS16: 2925.4.7.16 (cyclades.cyACSMgmt.cyAcsModel.ACS16) -- ACS32: 2925.4.7.32 (cyclades.cyACSMgmt.cyAcsModel.ACS32) -- ACS48: 2925.4.7.48 (cyclades.cyACSMgmt.cyAcsModel.ACS48) -- The above Enterprise OIDs will be used for registering each Model for NNM -- module. -------------------------------------------------------------------------------- cyAcsRebootStartedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName } DESCRIPTION "ACS is in process of rebooting. The name of the user who issued the command is contained in cyAcsTrapObjectUserName." --#SUMMARY "The appliance is rebooting. Command issued by user: %s." --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=15 ::= 1 cyAcsUserLoginTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSessionType} DESCRIPTION "This trap is sent when user logged into the appliance. The name of the user who logged in is contained in cyAcsTrapObjectUserName and the method used to log into appliance is contained in cyAcsTrapObjectSessionType." --#SUMMARY "A user logged into the appliance. User: %s. Session type: %d." --#ARGUMENTS { 0, 1 } --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=15 ::= 2 cyAcsUserLogoutTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSessionType } DESCRIPTION "A user logged out of the appliance. The name of the user who logged in is contained in cyAcsTrapObjectUserName and the method used to log into appliance is contained in cyAcsTrapObjectSessionType." --#SUMMARY "A user logged out of the appliance. User: %s. Session type: %d." --#ARGUMENTS { 0, 1} --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=15 ::= 3 cyAcsAuthenticationFailureTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName } DESCRIPTION "A user failed to authenticate with the appliance. The name of the user who failed to authenticate is contained in cyAcsTrapObjectUserName." --#SUMMARY "User authentication failed. User: %s." --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#CATEGORY "Error Events" --% TrapTypeEnum=15 ::= 4 cyAcsSerialSessionStartedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSerialPortName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectSerialSessionType } DESCRIPTION "This trap is sent when a serial session has started on particular port. The name of the user who is connected to the session is contained in cyAcsTrapObjectUserName. The serial port number on the appliance is contained in cyAcsTrapObjectSerialPort. The serial port name on the appliance is contained in cyAcsTrapObjectSerialPortName The type of protocol running on this serial port is contained in cyAcsTrapObjectSerialSessionType. " --#SUMMARY "Serial session started. User: %s. Port name: %s. Port number: %d. Session type: %d." --#ARGUMENTS { 0, 1, 2, 3 } --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 5 cyAcsSerialSessionStoppedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSerialPortName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectSerialSessionType } DESCRIPTION "This trap is sent when a serial session has stopped. The user who was connected to the session is contained in cyAcsTrapObjectUserName. The serial port number on the appliance is contained in cyAcsTrapObjectSerialPort. The serial port name on the appliance is contained in cyAcsTrapObjectSerialPortName The type of protocol running on this port is contained in cyAcsTrapObjectSerialSessionType." --#SUMMARY "Serial session stopped. User: %s. Port name: %s. Port number: %d. Session type: %d." --#ARGUMENTS { 0, 1, 2, 3 } --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 6 cyAcsPortAuthenticationFailureTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSerialPortName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectSerialSessionType } DESCRIPTION "This trap is sent when a serial session authentication fails. The name of the user who failed to authenticate is contained in cyAcsTrapObjectUserName. The serial port number on the appliance is contained in cyAcsTrapObjectSerialPort. The serial port name on the appliance is contained in cyAcsTrapObjectSerialPortName The type of protocol configured on this port is contained in cyAcsTrapObjectSerialSessionType." --#SUMMARY "Serial session authentication failed. User: %s. Port name: %s. Port number: %d. Session type: %d." --#ARGUMENTS { 0, 1, 2, 3 } --#SEVERITY INFORMATIONAL --#CATEGORY "Error Events" --% TrapTypeEnum=6 ::= 7 cyAcsPortAlertTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPortName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectAlertIndex, cyAcsTrapObjectAlertString, cyAcsTrapObjectAlertMessage } DESCRIPTION "The appliance detected a port alert on a serial port. The serial port number the port alert was detected on is contained in cyAcsTrapObjectSerialPort. The serial port name the port alert was detected on is contained in cyAcsTrapObjectSerialPortName. The index of the port alert that was detected is contained in cyAcsTrapObjectAlertIndex. The port alert that was detected is contained in cyAcsTrapObjectAlertString. The line text where the port alert was detected is contained in cyAcsTrapObjectAlertMessage." --#SUMMARY "A port alert was detected on a serial port. Port name: %s. Port number: %d. Port alert index: %d. Port alert string: %s. Line text: %s." --#ARGUMENTS { 0, 1, 2, 3, 4 } --#SEVERITY CRITICAL --#CATEGORY "Error Events" --% TrapTypeEnum=19 ::= 8 cyAcsPortPowerOnDetectTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPortName, cyAcsTrapObjectSerialPort } DESCRIPTION "The appliance has detected that the power on/off control signal (RS232C - DCD signal) is high on a serial port indicating that the server attached to the port is powered on. This trap is sent on initialization if the condition is detected. Subsequent traps occur only if there is a transition of the DCD signal from low to high. The affected serial port number is contained in cyAcsTrapObjectSerialPort. The affected serial port name is contained in cyAcsTrapObjectSerialPortName." --#SUMMARY "Power on detected on a serial port. Port name: %s. Port number: %d." --#ARGUMENTS { 0, 1} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=22 ::= 9 cyAcsPortPowerOffDetectTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPortName, cyAcsTrapObjectSerialPort } DESCRIPTION "The appliance has detected that the power on/off control signal (RS232C - DCD signal) is low on a serial port indicating that the server attached to the port is powered off. This trap is sent on initialization if the condition is detected. Subsequent traps occur only if there is a transition of the DCD signal from high to low. The affected serial port number is contained in cyAcsTrapObjectSerialPort. The affected serial port name is contained in cyAcsTrapObjectSerialPortName." --#SUMMARY "Power off detected on a serial port. Port name: %s. Port number: %d." --#ARGUMENTS { 0, 1} --#SEVERITY CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=23 ::= 10 cyAcsDaemonStarted TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectDaemonName } DESCRIPTION "This trap is generated when daemon in the appliance started. The daemon name is contained in cyAcsTrapObjectDaemonName. The name of the user who start the daemon is contained in cyAcsTrapObjectUserName. " --#SUMMARY "A daemon started. User: %s. Daemon name: %s." --#ARGUMENTS { 0, 1 } --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 11 cyAcsDaemonStoped TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectDaemonName } DESCRIPTION "This trap is generated when daemon in the appliance stopped. The daemon name is contained in cyAcsTrapObjectDaemonName. The name of the user who stop the daemon is contained in cyAcsTrapObjectUserName. " --#SUMMARY "A daemon stopped. User: %s. Daemon name: %s." --#ARGUMENTS { 0, 1 } --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 12 cyAcsAdminSessionTerminatedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectTargetUserName } DESCRIPTION "This trap is generated when one previous admin session is terminated by another admin user. The name of the user who terminated the session is contained in cyAcsTrapObjectUserName. The name of the user who was terminated from the session is contained in cyAcsTrapObjectTargetUserName." --#SUMMARY "Admin session terminated. Command issued by user: %s. Terminated user: %s." --#ARGUMENTS { 0, 1 } --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 13 cyAcsConfigurationSavedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName } DESCRIPTION "This trap is generated when 'saveconf' command is successful. cyAcsTrapObjectUserName is name of the user who executed saveconf." --#SUMMARY "Configuration saved to flash. User: %s." --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#CATEGORY "Configuration Events" --% TrapTypeEnum=9 ::= 14 cyAcsConfigurationActivatedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName } DESCRIPTION "This trap is generated when the configuration is activated. cyAcsTrapObjectUserName is name of the user who activated new configuration." --#SUMMARY "Configuration activated. User: %s." --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#CATEGORY "Configuration Events" --% TrapTypeEnum=9 ::= 15 cyAcsLocalUserAddedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectTargetUserName } DESCRIPTION "A new user has been added to the local user database. The name of the user who added the new user is contained in cyAcsTrapObjectUserName. The name of the new user is contained in cyAcsTrapObjectTargetUserName." --#SUMMARY "A user was added to the local user database. Command issued by user: %s. New user: %s." --#ARGUMENTS { 0, 1} --#SEVERITY INFORMATIONAL --#CATEGORY "Configuration Events" --% TrapTypeEnum=9 ::= 16 cyAcsLocalUserDeletedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectTargetUserName } DESCRIPTION "A user has been deleted from the local user database. The name of the user who deleted the user is contained in cyAcsTrapObjectUserName. The name of the user who was deleted is contained in cyAcsTrapObjectTargetUserName." --#SUMMARY "A user was deleted to the local user database. Command issued by user: %s. Deleted user: %s." --#ARGUMENTS {0,1} --#SEVERITY INFORMATIONAL --#CATEGORY "Configuration Events" --% TrapTypeEnum=9 ::= 17 cyAcsDataBufferFullThresholdLowTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectDataBufferSize } DESCRIPTION "This trap is generated when the appliance is managed by DsView and global data buffer has reached configured Low level Threshold. cyAcsTrapObjectDataBufferSize is current size of the buffer." --#SUMMARY "Data Buffering for DSView data log is getting full (low threshold). Buffer size: %d." --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#CATEGORY "Error Events" --% TrapTypeEnum=9 ::= 18 cyAcsDataBufferFullThresholdMedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectDataBufferSize } DESCRIPTION "This trap is generated when the appliance is managed by DsView and global data buffer has reached configured Med level Threshold. cyAcsTrapObjectDataBufferSize is current size of the buffer." --#SUMMARY "Data Buffering for DSView data log is almost full (medium threshold). Buffer size: %d." --#ARGUMENTS {0} --#SEVERITY ALERT --#CATEGORY "Error Events" --% TrapTypeEnum=9 ::= 19 cyAcsDataBufferFullLostDataTrap TRAP-TYPE ENTERPRISE cyACSMgmt DESCRIPTION "This trap is generated when the appliance is managed by DsView and global data buffer has exceeded beyond the size of buffer and data lost has occurred." --#SUMMARY "Data Buffering for DSView data log had data loss because buffer full." --#SEVERITY ALERT --#CATEGORY "Error Events" --% TrapTypeEnum=9 ::= 20 cyAcsApplianceLostDataTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectProcessID, cyAcsTrapObjectUserName } DESCRIPTION "This trap is generated when the appliance is managed by DsView and Appliance data lost occurred on ssh or telnet session. cyAcsTrapObjectProcessID is process id of the telnet or ssh session. cyAcsTrapObjectUserName is name of user who session is active and data lost occurred. " --#SUMMARY "Appliance data log loss. Process ID: %d. User: %s." --#ARGUMENTS { 0, 1} --#SEVERITY ALERT --#CATEGORY "Error Events" --% TrapTypeEnum=9 ::= 21 -------------------------------------------------------------------------------- -- Power Management Enterprise Traps -------------------------------------------------------------------------------- cyPMOnlineTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketCount, cyAcsTrapObjectPMType } DESCRIPTION "A power device attached to the appliance is online. The port number on the appliance that the power device is attached to is contained in cyAcsTrapObjectSerialPort. The power device number in the chain is contained in cyAcsTrapObjectPMNumber. The power device ID is contained in cyAcsTrapObjectPMId. The number of outlets of the power device is contained in cyAcsTrapObjectPMSocketCount. The vendor of the power device is contained in cyAcsTrapObjectPMType" --#SUMMARY "A power device is online. Port number: %d. Power device number: %d. Power device ID: %s. Number of sockets: %d. Type: %d." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 22 cyPMOfflineTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketCount, cyAcsTrapObjectPMType } DESCRIPTION "A power device attached to the appliance is offline. The port number on the appliance that the power device is attached to is contained in cyAcsTrapObjectSerialPort. The power device number in the chain is contained in cyAcsTrapObjectPMNumber. The power device ID is contained in cyAcsTrapObjectPMId. The number of outlets of the power device is contained in cyAcsTrapObjectPMSocketCount. The vendor of the power device is contained in cyAcsTrapObjectPMType" --#SUMMARY "A power device is offline. Port number: %d. Power device number: %d. Power device ID: %s. Number of sockets: %d. Type: %d." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY CRITICAL --#CATEGORY "Error Events" --% TrapTypeEnum=9 ::= 23 cyPMOutletOnTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMSocketNumber, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketName } DESCRIPTION "An outlet on a chain of power device has been issued the on command. The name of the user who issued the on command is contained in cyAcsTrapObjectUserName. The port number on the appliance that the chain of power device is attached to is contained in cyAcsTrapObjectSerialPort. The power device number in the chain is contained in cyAcsTrapObjectPMNumber. The ID of the power device is contained in cyAcsTrapObjectPMId. The socket number that was issued the on command is contained in cyAcsTrapObjectPMSocketNumber. The socket name that was issued the on command is contained in cyAcsTrapObjectPMSocketName." --#SUMMARY "The on command was issued to a power device socket. Command issued by user: %s. Power device port number: %d. Power device number: %d. Power device ID: %s. Socket number: %d. Socket name: %s." --#ARGUMENTS { 0, 1, 3, 4, 2, 5} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 24 cyPMOutletOffTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMSocketNumber, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketName } DESCRIPTION "An outlet on a chain of power device has been issued the off command. The port number on the appliance that the chain of power device is attached to is contained in cyAcsTrapObjectSerialPort. The power device number in the chain is contained in cyAcsTrapObjectPMNumber. The ID of the power device is contained in cyAcsTrapObjectPMId. The socket number that was issued the off command is contained in cyAcsTrapObjectPMSocketNumber. The socket name that was issued the off command is contained in cyAcsTrapObjectPMSocketName. The name of the user who issued the off command is contained in cyAcsTrapObjectUserName." --#SUMMARY "The off command was issued to a power device socket. Command issued by user: %s. Power device port number: %d. Power device number: %d. Power device ID: %s. Socket number: %d. Socket name: %s." --#ARGUMENTS { 0, 1, 3, 4, 2, 5} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 25 cyPMOutletCmdCycleTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMSocketNumber, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketName } DESCRIPTION "An outlet on a chain of power device has completed the cycle command. The port number on the appliance that the chain of power device is attached to is contained in cyAcsTrapObjectSerialPort. The power device number in the chain is contained in cyAcsTrapObjectPMNumber. The ID of the power device is contained in cyAcsTrapObjectPMId. The socket number that was issued the cycle command is contained in cyAcsTrapObjectPMSocketNumber. The socket name that was issued the cycle command is contained in cyAcsTrapObjectPMSocketName. The name of the user who issued the cycle command is contained in cyAcsTrapObjectUserName." --#SUMMARY "The cycle command was issued to a power device socket. Command issued by user: %s. Power device port number: %d. Power device number: %d. Power device ID: %s. Socket number: %d. Socket name: %s." --#ARGUMENTS { 0, 1, 3, 4, 2, 5} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 26 cyPMMaxLoadThresholdReachedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMPhase, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "A power device attached to the appliance exceeded the total load maximum threshold. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The IPDU# that exceeded the total load maximum threshold is contained in the cyAcsTrapObjectPMNumber. The ID of the IPDU that exceeded the total load maximum threshold is contained in the cyAcsTrapObjectPMId. The Phase of the IPDU that detected the problem is contained in the cyAcsTrapObjectPMPhase. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device exceeded the total load maximum threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Phase: %s. Current detected: %s amps." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY ALERT --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 27 cyPMMinLoadThresholdReachedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMPhase, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "A power device attached to the appliance exceeded the total load minimum threshold. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The IPDU# that exceeded the total load minimum threshold is contained in the cyAcsTrapObjectPMNumber. The ID of the IPDU that exceeded the total load maximum threshold is contained in the cyAcsTrapObjectPMId. The Phase of the IPDU that detected the problem is contained in the cyAcsTrapObjectPMPhase. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device is back below the alarm threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Phase: %s. Current detected: %s amps." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 28 --------------------------------------- -- Appliance Alert Event --------------------------------------- cyAcsApplianceAlertTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectAlertIndex, cyAcsTrapObjectAlertString, cyAcsTrapObjectAlertMessage } DESCRIPTION "An appliance alert was detected on a ssh or telnet session. The name of user who was logged into the appliance when trap occurred is contained in cyAcsTrapObjectUserName. The index of the appliance alert that was detected in the message is contained in cyAcsTrapObjectAlertIndex. The appliance alert that was detected is contained in cyAcsTrapObjectAlertString. The line text where the appliance alert was detected is contained in cyAcsTrapObjectAlertMessage." --#SUMMARY "An appliance alert was detected. User: %s. Alert index: %d. Alert string: %s. Line text: %s." --#ARGUMENTS { 0, 1, 2, 3} --#SEVERITY CRITICAL --#CATEGORY "Error Events" --% TrapTypeEnum=9 ::= 29 --------------------------------------------------------------- -- Firmware Upgrade Traps when the process is started by DSView --------------------------------------------------------------- cyAcsFirmwareUpgradeStarted TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapFirmwareVersion, cyAcsTrapNewFirmwareVersion } DESCRIPTION "The appliance has started an upgrade of a software image by DSView. The name of the user who initiate the process is contained in cyAcsTrapObjectUserName. The current firmware version is contained in cyAcsTrapFirmwareVersion. The new firmware version is contained in cyAcsTrapNewFirmwareVersion." --#SUMMARY "Image upgrade started by DSView. User: %s. Current version: %s. New version: %s." --#ARGUMENTS { 0, 1, 2} --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 30 cyAcsFirmwareUpgradeResultsTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapFirmwareUpgradeResult , cyAcsTrapNewFirmwareVersion } DESCRIPTION "This trap is generated when Firmware upgraded is done to indicate the result. The new FW version is contained in cyAcsTrapNewFirmwareVersion. The result of the process is contained in cyAcsTrapFirmwareUpgradeResult." --#SUMMARY "Image upgrade result. Result: %d. New firmware version: %s." --#ARGUMENTS {0,1} --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 31 ------------------------------ -- PM Firmware Upgrade Traps ------------------------------ cyAcsPMFirmwareUpgradeStarted TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapFirmwareVersion, cyAcsTrapNewFirmwareVersion } DESCRIPTION "The appliance has started an upgrade of the PM software. The name of the user who initiate the process is contained in cyAcsTrapObjectUserName. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The IPDU# that gone beneath the minimum threshold is contained in the cyAcsTrapObjectPMNumber. The current firmware version is contained in cyAcsTrapFirmwareVersion. The new firmware version is contained in cyAcsTrapNewFirmwareVersion." --#SUMMARY "PM image upgrade started. User: %s. Power device port number: %d. Power device number: %d. Current version: %s. New version: %s." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 32 cyAcsPMFirmwareUpgradeResultsTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapFirmwareUpgradeResult, cyAcsTrapNewFirmwareVersion } DESCRIPTION "This trap is generated when Firmware upgraded is done to indicate the result. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The IPDU# that gone beneath the minimum threshold is contained in the cyAcsTrapObjectPMNumber. The new FW version is contained in cyAcsTrapNewFirmwareVersion. The result of the process is contained in cyAcsTrapFirmwareUpgradeResult." --#SUMMARY "PM image upgrade result. Power device port number:%d. Power device number: %d. Result: %d. New firmware version: %s." --#ARGUMENTS {0,1,2,3} --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 33 cyAcsSerialSessionStoppedPortInUseTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSerialPortName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectSerialSessionType } DESCRIPTION "This trap is sent when a serial session has stopped. But, there is still active sessions on this port. The user who was connected to the session is contained in cyAcsTrapObjectUserName. The serial port number on the appliance is contained in cyAcsTrapObjectSerialPort. The serial port name on the appliance is contained in cyAcsTrapObjectSerialPortName The type of protocol running on this port is contained in cyAcsTrapObjectSerialSessionType." --#SUMMARY "Serial session stopped. User: %s. Port name: %s. Port number: %d. Session type: %d." --#ARGUMENTS { 0, 1, 2, 3 } --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 35 -------------------------------------------------------------------------------- -- New Power Management Enterprise Traps -------------------------------------------------------------------------------- cyPMOutletStatusOnTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketNumber, cyAcsTrapObjectPMSocketName } DESCRIPTION "An outlet on a chain of power device has changed to the on state. The port number on the appliance that the chain of power device is attached to is contained in cyAcsTrapObjectSerialPort. The ID of the power device is contained in cyAcsTrapObjectPMId. The socket number that has changed to the on state is contained The number of the power device is contained in the cyAcsTrapObjectPMNumber. in cyAcsTrapObjectPMSocketNumber. The socket name that has changed to the on state is contained in cyAcsTrapObjectPMSocketName." --#SUMMARY "Power device socket state changed to on. Power device port number: %d. Power device number: %d. Power device ID: %s. Socket number: %d. Socket name: %s." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 36 cyPMOutletStatusOffTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketNumber, cyAcsTrapObjectPMSocketName } DESCRIPTION "An outlet on a chain of power device has changed to the off state. The port number on the appliance that the chain of power device is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device is contained in the cyAcsTrapObjectPMNumber. The ID of the power device is contained in cyAcsTrapObjectPMId. The socket number that has changed to the off state is contained in cyAcsTrapObjectPMSocketNumber. The socket name that has changed to the off state is contained in cyAcsTrapObjectPMSocketName." --#SUMMARY "Power device socket state changed to off. Power device port number: %d. Power device number: %d. Power device ID: %s. Socket number: %d. Socket name: %s." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 37 cyPMOutletOnSenseFailTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketNumber, cyAcsTrapObjectPMSocketName } DESCRIPTION "A power device attached to the appliance has detected an on sense failure for a socket. An on sense failure occurs when a socket should be in the on state but is actually in the off state. The port number on the appliance that the chain of power device is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device is contained in the cyAcsTrapObjectPMNumber. The ID of the power device is contained in cyAcsTrapObjectPMId. The socket number that has changed to the on state is contained in cyAcsTrapObjectPMSocketNumber. The socket name that has changed to the on state is contained in cyAcsTrapObjectPMSocketName." --#SUMMARY "Power device socket on sense failure. Power device port number: %d. Power device number: %d. Power device ID: %s. Socket number: %d. Socket name: %s." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 38 cyPMOutletOffSenseFailTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketNumber, cyAcsTrapObjectPMSocketName } DESCRIPTION "A power device attached to the appliance has detected an off sense failure for a socket. An off sense failure occurs when a socket should be in the off state but is actually in the on state. The port number on the appliance that the chain of power device is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device is contained in the cyAcsTrapObjectPMNumber. The ID of the power device is contained in cyAcsTrapObjectPMId. The socket number that has changed to the on state is contained in cyAcsTrapObjectPMSocketNumber. The socket name that has changed to the on state is contained in cyAcsTrapObjectPMSocketName." --#SUMMARY "Power device socket off sense failure. Power device port number: %d. Power device number: %d. Power device ID: %s. Socket number: %d. Socket name: %s." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 39 cyPMOutletNameChangedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketNumber, cyAcsTrapObjectPMSocketOldName, cyAcsTrapObjectPMSocketName } DESCRIPTION "The name of socket was changed. The port number on the appliance that the chain of power device is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device is contained in the cyAcsTrapObjectPMNumber. The ID of the power device is contained in cyAcsTrapObjectPMId. The socket number that has changed to the on state is contained in cyAcsTrapObjectPMSocketNumber. The socket name that has changed to the on state is contained in cyAcsTrapObjectPMSocketName." --#SUMMARY "Power device socket name was changed. Power device port number: %d. Power device number: %d. Power device ID: %s. Socket number: %d. Old socket name: %s. New socket name: %s." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 40 cyPMInletTotalLoadHighTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMPhase } DESCRIPTION "A power device attached to the appliance has exceeded the maximum threshold for total load of an inlet. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The number of the IPDU that has exceeded the maximum threshold for total load of an inlet is contained in the cyAcsTrapObjectPMNumber. The IPDU ID that has exceeded the maximum threshold for total load of an inlet is contained in the cyAcsTrapObjectPMId. The inlet of the power device is contained in the cyAcsTrapObjectPMPhase." --#SUMMARY "Power device inlet exceeded the total load maximum threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Inlet: %s. " --#ARGUMENTS { 0, 1, 2, 3} --#SEVERITY ALERT --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 41 cyPMInletTotalLoadLowTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMPhase } DESCRIPTION "A power device attached to the appliance has gone beneath the minimum threshold for total load of an inlet. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The number of the IPDU that has exceeded the maximum threshold for total load of an inlet is contained in the cyAcsTrapObjectPMNumber. The IPDU ID that has gone beneath the minimum threshold for total load of an inlet is contained in the cyAcsTrapObjectPMId. The inlet of the power device is contained in the cyAcsTrapObjectPMPhase." --#SUMMARY "Power device inlet is back below the total load minimum threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Inlet: %s. " --#ARGUMENTS { 0, 1, 2, 3} --#SEVERITY ALERT --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 42 cyPMIdChangedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMIdOld, cyAcsTrapObjectPMId, cyAcsTrapObjectPMType } DESCRIPTION "The ID of the power device was changed. The port number on the appliance that the power device is attached to is contained in cyAcsTrapObjectSerialPort. The power device number in the chain is contained in cyAcsTrapObjectPMNumber. The old power device ID is contained in cyAcsTrapObjectPMIdOld. The new power device ID is contained in cyAcsTrapObjectPMId. The vendor of the power device is contained in cyAcsTrapObjectPMType." --#SUMMARY "Power device ID was changed. Power device port number: %d. Power device number: %d. Power device old ID: %s. Power device new ID: %s. Type: %d." --#ARGUMENTS { 0, 1, 2, 3, 4} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 43 cyPMHwOcpTripped TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName } DESCRIPTION "This trap is generated when the HW overcurrent protection mechanism is tripped. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The number of the power device that was tripped is contained in the cyAcsTrapObjectPMNumber. The ID of the power device that was tripped is contained in the cyAcsTrapObjectPMId. The Type of the PDU Element that detected the event is contained in the cyAcsTrapObjectPMElementType. The Name of the Pdu Element that detected the event is contained in the cyAcsTrapObjectPMElementName. " --#SUMMARY "Power device HW overcurrent protection was tripped. Power Device port number:%d. Power device number: %d. Power device ID: %s. Elem Type: %s. Elem Name: %s." --#ARGUMENTS {0, 1, 2, 3, 4} --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 44 cyPMHwOcpReset TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName } DESCRIPTION "This trap is generated when the HW overcurrent protection mechanism in Cyclades-PM42 is reset. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The number of the power device whose HW OCP was reset is contained in the cyAcsTrapObjectPMNumber. The ID of the power device whose HW OCP was reset is contained in the cyAcsTrapObjectPMId. The Type of the PDU Element that detected the event is contained in the cyAcsTrapObjectPMElementType. The Name of the Pdu Element that detected the event is contained in the cyAcsTrapObjectPMElementName. " --#SUMMARY "Power device HW overcurrent protection was reset. Power Device port number:%d. Power device number: %d. Power device ID: %s. Elem Type: %s. Elem Name: %s." --#ARGUMENTS {0, 1, 2, 3, 4} --#SEVERITY INFORMATIONAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 45 cyPMMaxLoadBackTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "The current on a power device attached to the appliance is back to normal. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The power device that detected the event is contained in the cyAcsTrapObjectPMNumber. The ID of the power device that detected the event is contained in the cyAcsTrapObjectPMId. The Type of the power device Element that detected the event is contained in the cyAcsTrapObjectPMElementType. The Name of the power device Element that detected the event is contained in the cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device normal current restored. Power device port number: %d. Power device number: %d. Power device ID: %s. Elem Type: %s. Elem Name: %s. Current detected: %s amps." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 46 cyPMMaxLoadHighTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "The current on a power device attached to the appliance is above its high critical threshold. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The power device that detected the problem is contained in the cyAcsTrapObjectPMNumber. The ID of the power device that detected the problem is contained in the cyAcsTrapObjectPMId. The Type of the power device Element that detected the problem is contained in the cyAcsTrapObjectPMElementType. The Name of the power device Element that detected the problem is contained in the cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device current is above its high critical threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Elem Type: %s. Elem Name: %s. Current detected: %s amps." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 47 cyPMMinLoadLowTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "The current on a power device attached to the appliance is below its low critical threshold. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The power device that detected the problem is contained in the cyAcsTrapObjectPMNumber. The ID of the power device that detected the problem is contained in the cyAcsTrapObjectPMId. The Type of the power device Element that detected the problem is contained in the cyAcsTrapObjectPMElementType. The Name of the power device Element that detected the problem is contained in the cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device current is below its low critical threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Elem Type: %s. Elem Name: %s. Current detected: %s amps." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 48 cyPMWarnLoadTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "The current on a power device attached to the appliance is above its high warning threshold. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The power device that detected the problem is contained in the cyAcsTrapObjectPMNumber. The ID of the power device that detected the problem is contained in the cyAcsTrapObjectPMId. The Type of the power device Element that detected the problem is contained in the cyAcsTrapObjectPMElementType. The Name of the power device Element that detected the problem is contained in the cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device current is above its high warning threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Elem Type: %s. Elem Name: %s. Current detected: %s amps." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 49 cyPMLowLoadLowTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "The current on a power device attached to the appliance is below its low warning threshold. The port number on the appliance that the power device is attached to is contained in the cyAcsTrapObjectSerialPort. The power device that detected the problem is contained in the cyAcsTrapObjectPMNumber. The ID of the power device that detected the problem is contained in the cyAcsTrapObjectPMId. The Type of the power device Element that detected the problem is contained in the cyAcsTrapObjectPMElementType. The Name of the power device Element that detected the problem is contained in the cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device current is below its low warning threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Elem Type: %s. Elem Name: %s. Current detected: %s amps." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 50 cyPMOutletCycleFinishedTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectUserName, cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMSocketNumber, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMSocketName } DESCRIPTION "An outlet on a chain of power device has completed the cycle command. The port number on the appliance that the chain of power device is attached to is contained in cyAcsTrapObjectSerialPort. The power device number in the chain is contained in cyAcsTrapObjectPMNumber. The ID of the power device is contained in cyAcsTrapObjectPMId. The socket number that was issued the cycle command is contained in cyAcsTrapObjectPMSocketNumber. The socket name that was issued the cycle command is contained in cyAcsTrapObjectPMSocketName. The name of the user who issued the cycle command is contained in cyAcsTrapObjectUserName." --#SUMMARY "The socket was power cycled. Command issued by user: %s. Power device port number: %d. Power device number: %d. Power device ID: %s. Socket number: %d. Socket name: %s." --#ARGUMENTS { 0, 1, 3, 4, 2, 5} --#SEVERITY MINOR --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 51 cyPMSensorThresholdNormalTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "A sensor attached to the appliance cleared its alarm. The port number of the appliance where the sensor is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device where the sensor is attached is contained in cyAcsTrapObjectPMNumber. The ID of the power device where the sensor is attached is contained in cyAcsTrapObjectPMId. The Type of the sensor is contained in cyAcsTrapObjectPMElementType. The Name of the sensor is contained in cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device environment sensor alarm was cleared. Power device port number: %d. Power device number: %d. Power device ID: %s. Sensor Type: %s. Sensor Name: %s. Current value: %s." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 52 cyPMSensorThresholdHighCriticalTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "A sensor attached to the appliance is above its high critical threshold. The port number of the appliance where the sensor is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device where the sensor is attached is contained in cyAcsTrapObjectPMNumber. The ID of the power device where the sensor is attached is contained in cyAcsTrapObjectPMId. The Type of the sensor is contained in cyAcsTrapObjectPMElementType. The Name of the sensor is contained in cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device environment sensor is above its high critical threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Sensor Type: %s. Sensor Name: %s. Current value: %s." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 53 cyPMSensorThresholdHighWarningTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "A sensor attached to the appliance is above its high warning threshold. The port number of the appliance where the sensor is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device where the sensor is attached is contained in cyAcsTrapObjectPMNumber. The ID of the power device where the sensor is attached is contained in cyAcsTrapObjectPMId. The Type of the sensor is contained in cyAcsTrapObjectPMElementType. The Name of the sensor is contained in cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device environment sensor is above its high warning threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Sensor Type: %s. Sensor Name: %s. Current value: %s." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 54 cyPMSensorThresholdLowWarningTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "A sensor attached to the appliance is below its low warning threshold. The port number of the appliance where the sensor is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device where the sensor is attached is contained in cyAcsTrapObjectPMNumber. The ID of the power device where the sensor is attached is contained in cyAcsTrapObjectPMId. The Type of the sensor is contained in cyAcsTrapObjectPMElementType. The Name of the sensor is contained in cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device environment sensor is below its low warning threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Sensor Type: %s. Sensor Name: %s. Current value: %s." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 55 cyPMSensorThresholdLowCriticalTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "A sensor attached to the appliance is below its low critical threshold. The port number of the appliance where the sensor is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device where the sensor is attached is contained in cyAcsTrapObjectPMNumber. The ID of the power device where the sensor is attached is contained in cyAcsTrapObjectPMId. The Type of the sensor is contained in cyAcsTrapObjectPMElementType. The Name of the sensor is contained in cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device environment sensor is below its low critical threshold. Power device port number: %d. Power device number: %d. Power device ID: %s. Sensor Type: %s. Sensor Name: %s. Current value: %s." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 56 cyPMSensorThresholdDigitalSensorAlarmTrap TRAP-TYPE ENTERPRISE cyACSMgmt VARIABLES { cyAcsTrapObjectSerialPort, cyAcsTrapObjectPMNumber, cyAcsTrapObjectPMId, cyAcsTrapObjectPMElementType, cyAcsTrapObjectPMElementName, cyAcsTrapObjectPMCurrentValue } DESCRIPTION "A digital sensor attached to the appliance is in its alarm state. The port number of the appliance where the sensor is attached to is contained in cyAcsTrapObjectSerialPort. The number of the power device where the sensor is attached is contained in cyAcsTrapObjectPMNumber. The ID of the power device where the sensor is attached is contained in cyAcsTrapObjectPMId. The Type of the sensor is contained in cyAcsTrapObjectPMElementType. The Name of the sensor is contained in cyAcsTrapObjectPMElementName. The current value detected when this trap was originated is contained in cyAcsTrapObjectPMCurrentValue." --#SUMMARY "Power device environment digital sensor changed to alarm state. Power device port number: %d. Power device number: %d. Power device ID: %s. Sensor Type: %s. Sensor Name: %s. Current value: %s." --#ARGUMENTS { 0, 1, 2, 3, 4, 5} --#SEVERITY NON-CRITICAL --#CATEGORY "Status Events" --% TrapTypeEnum=9 ::= 57 END