-- Avocent Vendor Cyclades CS Family MIB OID Tree -- Release 1.0.0 May/15/2007 AVOCENT-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM SNMPv2-SMI ; avocent OBJECT IDENTIFIER ::= { enterprises 10418 } cycladesCS OBJECT IDENTIFIER ::= { avocent 15 } ccsProducts OBJECT IDENTIFIER ::= { cycladesCS 1 } cCS4001 OBJECT IDENTIFIER ::= { ccsProducts 1 } cCS4004 OBJECT IDENTIFIER ::= { ccsProducts 2 } cCS4008 OBJECT IDENTIFIER ::= { ccsProducts 3 } cCS4016 OBJECT IDENTIFIER ::= { ccsProducts 4 } END -- Cyclades CS Family MIB management AVOCENT-CYCLADES-CS-MIB DEFINITIONS ::= BEGIN IMPORTS cycladesCS FROM AVOCENT-MIB MODULE-IDENTITY FROM SNMPv2-SMI; ccsManagement MODULE-IDENTITY LAST-UPDATED "200704260000Z" ORGANIZATION "Avocent Corporation" CONTACT-INFO "postal: Avocent Corporation 3541 Gateway Boulevard Fremont, CA 94538, USA e-mail: Technical Support techsupport@avocent.com" DESCRIPTION "This file defines the Avocent MIB extensions to Cyclades CS Family products" REVISION "200704260000Z" DESCRIPTION "First Draft" ::= { cycladesCS 2 } -- Current Avocent Cyclades CS Family core mib table entries: -- ccsSystem OBJECT-IDENTITY ::= { ccsManagement 1 } -- ccsConfiguration OBJECT-IDENTITY ::= { ccsManagement 2 } -- ccsInformation OBJECT-IDENTITY ::= { ccsManagement 3 } -- ccsAdministration OBJECT-IDENTITY ::= { ccsManagement 4 } -- ccsPowerManagement OBJECT-IDENTITY ::= { ccsManagement 5 } END AVOCENT-CYCLADES-CS-SYS-MIB DEFINITIONS ::= BEGIN IMPORTS ccsManagement FROM AVOCENT-CYCLADES-CS-MIB OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, Integer32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; ccsSystem MODULE-IDENTITY LAST-UPDATED "200704260000Z" ORGANIZATION "Avocent Corporation" CONTACT-INFO "postal: Avocent Corporation 3541 Gateway Boulevard Fremont, CA 94538, USA e-mail: Technical Support techsupport@avocent.com" DESCRIPTION "This module defines Cyclades CS Family System Information objects" REVISION "200704260000Z" DESCRIPTION "First Draft" ::= { ccsManagement 1 } ccsPname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The product's name - CCS40xx (xx - the number of the serial ports)" ::= { ccsSystem 1 } ccsVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The firmware's version" ::= {ccsSystem 2} ccsPower OBJECT-IDENTITY STATUS current DESCRIPTION "It gives information about Power Supply" ::= { ccsSystem 3 } ccsPwNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the power supplies" ::= { ccsPower 1 } ccsPw1 OBJECT-TYPE SYNTAX INTEGER { noinstalled(0), powerON(1), powerOFF(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the first power supply" ::= { ccsPower 2 } ccsPw2 OBJECT-TYPE SYNTAX INTEGER { noinstalled(0), powerON(1), powerOFF(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the second power supply" ::= { ccsPower 3 } ccsPcmcia OBJECT-IDENTITY STATUS current DESCRIPTION "PCMCIA card information" ::= {ccsSystem 4} ccsNPcmcia OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the cards PCMCIA available" ::= { ccsPcmcia 1 } ccsCardIdentTable OBJECT-TYPE SYNTAX SEQUENCE OF CcsCardIdentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Card identification" ::= { ccsPcmcia 2 } ccsCardIdentEntry OBJECT-TYPE SYNTAX CcsCardIdentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "One particular association between PCMCIA socket and card identification" INDEX { ccsCardIdentIndex } ::= { ccsCardIdentTable 1 } CcsCardIdentEntry ::= SEQUENCE { ccsCardIdentIndex Integer32, ccsCardIdentProd DisplayString, ccsCardIdentMan DisplayString , ccsCardIdentFunc DisplayString, ccsCardIdentPCI DisplayString } ccsCardIdentIndex OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS read-only STATUS current DESCRIPTION "number to identifier the socket Card" ::= { ccsCardIdentEntry 1 } ccsCardIdentProd OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Product identification strings" ::= { ccsCardIdentEntry 2 } ccsCardIdentMan OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Manufacturer ID codes" ::= { ccsCardIdentEntry 3 } ccsCardIdentFunc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Function ID code" ::= { ccsCardIdentEntry 4 } ccsCardIdentPCI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PCI ID" ::= { ccsCardIdentEntry 5 } ccsCardConfTable OBJECT-TYPE SYNTAX SEQUENCE OF CcsCardConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table has the socket configuration " ::= { ccsPcmcia 3 } ccsCardConfEntry OBJECT-TYPE SYNTAX CcsCardConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "One particular association between PCMCIA socket and its configuration" INDEX { ccsCardConfIndex } ::= { ccsCardConfTable 1 } CcsCardConfEntry ::= SEQUENCE { ccsCardConfIndex Integer32, ccsCardConfPower DisplayString, ccsCardConfType DisplayString , ccsCardConfInter DisplayString, ccsCardConfFunc DisplayString, ccsCardConfCardv DisplayString, ccsCardConfPort1 DisplayString, ccsCardConfPort2 DisplayString } ccsCardConfIndex OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS read-only STATUS current DESCRIPTION "number to identifier the socket PCMCIA" ::= { ccsCardConfEntry 1 } ccsCardConfPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Power Settings" ::= { ccsCardConfEntry 2 } ccsCardConfType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Interface Type" ::= { ccsCardConfEntry 3 } ccsCardConfInter OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Interrupt number" ::= { ccsCardConfEntry 4 } ccsCardConfFunc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "function" ::= { ccsCardConfEntry 5 } ccsCardConfCardv OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Card values" ::= { ccsCardConfEntry 6 } ccsCardConfPort1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "I/O Port 1" ::= { ccsCardConfEntry 7 } ccsCardConfPort2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "I/O Port 2" ::= { ccsCardConfEntry 8 } ccsCardStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF CcsCardStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table has the current socket status flags " ::= { ccsPcmcia 4 } ccsCardStatusEntry OBJECT-TYPE SYNTAX CcsCardStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "One particular association between PCMCIA socket and its status" INDEX { ccsCardStatusIndex } ::= { ccsCardStatusTable 1 } CcsCardStatusEntry ::= SEQUENCE { ccsCardStatusIndex Integer32, ccsCardStatusCard DisplayString, ccsCardStatusFunc DisplayString } ccsCardStatusIndex OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS read-only STATUS current DESCRIPTION "number to identifier the socket PCMCIA" ::= { ccsCardStatusEntry 1 } ccsCardStatusCard OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current Card State" ::= { ccsCardStatusEntry 2 } ccsCardStatusFunc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current Function" ::= { ccsCardStatusEntry 3 } ccsFlashSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total amount of flash memory in Mbytes" ::= {ccsSystem 5} ccsRAMSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total amount of RAM in Mbytes" ::= {ccsSystem 6} ccsCPUfreq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "CPU clock in MHz" ::= {ccsSystem 7} ccsDevId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The product's identifier" ::= { ccsSystem 8 } END AVOCENT-CYCLADES-CS-CONF-MIB DEFINITIONS ::= BEGIN IMPORTS ccsManagement FROM AVOCENT-CYCLADES-CS-MIB InterfaceIndexOrZero FROM IF-MIB MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, IpAddress, Integer32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; ccsConfiguration MODULE-IDENTITY LAST-UPDATED "200704260000Z" ORGANIZATION "Avocent Corporation" CONTACT-INFO "postal: Avocent Corporation 3541 Gateway Boulevard Fremont, CA 94538, USA e-mail: Technical Support techsupport@avocent.com" DESCRIPTION "This module defines Cyclades CS Family Configuration objects" REVISION "200704260000Z" DESCRIPTION "First Draft" ::= { ccsManagement 2 } -- Current Avocent Cyclades CS Family Configuration core mib table entries : -- ccsHostName OBJECT-TYPE ::= { ccsConfiguration 1 } -- ccsConsoleBanner OBJECT-TYPE ::= { ccsConfiguration 2 } -- ccsMotd OBJECT-TYPE ::= { ccsConfiguration 3 } -- ccsEthItf OBJECT-IDENTITY ::= { ccsConfiguration 4 } -- ccsNameService OBJECT-IDENTITY ::= { ccsConfiguration 5 } -- ccsSerialPortConf OBJECT-IDENTITY ::= { ccsConfiguration 6 } ccsHostName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Host Name " ::= { ccsConfiguration 1 } ccsConsoleBanner OBJECT-TYPE SYNTAX DisplayString (SIZE (1..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The console banner " ::= { ccsConfiguration 2 } ccsMotd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "The motd message " ::= { ccsConfiguration 3 } ccsEthItf OBJECT-IDENTITY STATUS current DESCRIPTION "The configuration of the Ethernet Interface" ::= { ccsConfiguration 4 } ccsEthDhcpc OBJECT-TYPE SYNTAX INTEGER { inactive(0), -- DHCP is inactive active(1), -- DHCP is active restore(2) -- DHCP is active and CCS saves the last parameters -- assigned by the server } MAX-ACCESS read-write STATUS current DESCRIPTION "The CCS can request all of its ethernet parameters to a DHCP server" ::= { ccsEthItf 1 } ccsEthIPaddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is the IP address of the Ethernet Interface" ::= { ccsEthItf 2 } ccsEthIPmask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The mask fot the Ethernet network" ::= { ccsEthItf 3 } ccsEthMTU OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Maximum Transmission Unit size, wich determines whether or not packets should be broken up" ::= { ccsEthItf 4 } ccsEthIPaddr2 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Ethernet secondary IP address" ::= { ccsEthItf 5 } ccsEthIPmask2 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Ethernet secondary IP mask" ::= { ccsEthItf 6 } ccsNameService OBJECT-IDENTITY STATUS current DESCRIPTION "The Name Service configuration" ::= { ccsConfiguration 5 } ccsResolverOrder OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) MAX-ACCESS read-write STATUS current DESCRIPTION "It specifies how host lookups are to be performed. Valid values : empty, 'hosts', 'bind', 'hosts, bind', 'bind, hosts' " ::= { ccsNameService 1 } ccsMultipleIP OBJECT-TYPE SYNTAX DisplayString (SIZE (0..3)) MAX-ACCESS read-write STATUS current DESCRIPTION "Valid values are ON or OFF. If set to ON, the resolve library will return all valid addresses for a host that appears in the /etc/hosts file, instead of only the first. " ::= { ccsNameService 2 } ccsDNSserv OBJECT-IDENTITY STATUS current DESCRIPTION "The DNS server configuration" ::= { ccsNameService 3 } ccsDNSpriserv OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Internet Address (in dot notation) of primary name server that the resolver should query." ::= { ccsDNSserv 1 } ccsDNSsecserv OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Internet Address (in dot notation) of secondary name server that the resolver should query." ::= { ccsDNSserv 2 } ccsDNSdomain OBJECT-TYPE SYNTAX DisplayString (SIZE (1..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "Local domain name ." ::= { ccsDNSserv 3 } ccsSerialPortConf OBJECT-IDENTITY STATUS current DESCRIPTION "The PortSlave configuration - pslave.conf file. It configures the all serial ports." ::= { ccsConfiguration 6 } ccsSerialGlobal OBJECT-IDENTITY STATUS current DESCRIPTION "These parameters have the prefix conf. in the pslave.conf file" ::= { ccsSerialPortConf 1 } ccsSerialInclude OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "File used in centralized management." ::= { ccsSerialGlobal 1 } ccsSerialNFS OBJECT-TYPE SYNTAX DisplayString (SIZE (0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Remote Network File System where data buffering will be written instead of the default directory '/var/run/DB'." ::= { ccsSerialGlobal 2 } ccsSerialLockDir OBJECT-TYPE SYNTAX DisplayString (SIZE (0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "The lock directory for the CCS." ::= { ccsSerialGlobal 3 } ccsSerialRlogin OBJECT-TYPE SYNTAX DisplayString (SIZE (0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Location of the rlogin binary that accepts the -i flag." ::= { ccsSerialGlobal 4 } ccsSerialPppd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Location of the pppd binary." ::= { ccsSerialGlobal 5 } ccsSerialTelnet OBJECT-TYPE SYNTAX DisplayString (SIZE (0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Location of the telnet application" ::= { ccsSerialGlobal 6 } ccsSerialSsh OBJECT-TYPE SYNTAX DisplayString (SIZE (0..50)) MAX-ACCESS read-write STATUS current DESCRIPTION "Location of the ssh application" ::= { ccsSerialGlobal 7 } ccsSerialLocalLogins OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) -- possible to login to the CCS directly by placing a ! } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is only necessary when authentication is being performed for a port. This is useful if the Radius authentication server is down." ::= { ccsSerialGlobal 8 } ccsSerialFacility OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This value (0-7) is the Local facility sent to the syslog daemon." ::= { ccsSerialGlobal 9 } ccsSerialDBFacility OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This value (0-7) is the Local facility sent to the syslog daemon with the data when ." ::= { ccsSerialGlobal 10 } ccsSerialGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF CcsGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This associates group name and its users" ::= { ccsSerialGlobal 11 } ccsgroupEntry OBJECT-TYPE SYNTAX CcsGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "One particular association between group name and its users" INDEX { ccsgroupIndex } ::= { ccsSerialGroupTable 1 } CcsGroupEntry ::= SEQUENCE { ccsGroupIndex InterfaceIndexOrZero, ccsGroupName DisplayString, ccsGroupUsers DisplayString } ccsGroupIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "number to identifier the group" ::= { ccsgroupEntry 1 } ccsGroupName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Group Name " ::= { ccsgroupEntry 2 } ccsGroupUsers OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) MAX-ACCESS read-write STATUS current DESCRIPTION "The users names " ::= { ccsgroupEntry 3 } ccsSerialSpec OBJECT-IDENTITY STATUS current DESCRIPTION "These parameters have the prefix all. or sxx. in the pslave.conf file" ::= { ccsSerialPortConf 2 } ccsSerialPortTable OBJECT-TYPE SYNTAX SEQUENCE OF CcsSPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the specific configuration to serial port" ::= { ccsSerialSpec 1 } ccssportEntry OBJECT-TYPE SYNTAX CcsSPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "One particular serial port configuration" INDEX { ccsSPortNumber } ::= { ccsSerialPortTable 1 } CcsSPortEntry ::= SEQUENCE { ccsSPortNumber InterfaceIndexOrZero, -- 0 == all. X == ttyX sX. ccsSPortTty DisplayString, -- associate device ccsSPortName DisplayString, -- alias name ccsSPortSpeed INTEGER, -- physical port configuration ccsSPortDataSize Integer32, ccsSPortStopBits Integer32, ccsSPortParity DisplayString, ccsSPortFlowCtrl DisplayString, ccsSPortDTRdelay Integer32, ccsSPortDCDCtrl INTEGER, ccsSPortLogUtmp INTEGER, -- log into UTMP ccsSPortLogWtmp INTEGER, -- log into WTMP ccsSPortLogform DisplayString, ccsSPortAuthtype DisplayString, -- authentication type ccsSPortAuthSrv1 IpAddress, -- IP address of the primary authentication server ccsSPortAccSrv1 IpAddress, -- IP address of the primarty accounting server ccsSPortAuthTmo Integer32, -- time out per authentication query ccsSPortAuthRetr Integer32, -- authentication number of retries ccsSPortAuthSrv2 IpAddress, -- IP address of the secondary authentication server ccsSPortAccSrv2 IpAddress, -- IP address of the secondary accounting server ccsSPortAuthSecret DisplayString, -- secret used in authentication ccsSPortAuthRadP INTEGER, -- accept RADIUS' user without password ccsSPortAuthAcc DisplayString, -- access restrition on Users ccsSPortProtocol DisplayString, -- Profile ccsSPortRemoteIP DisplayString, -- remote IP address ccsSPortSocketPort DisplayString, -- number of socket port ccsSPortRemHost IpAddress, -- IP address of the remote Host ccsSPortBanner DisplayString, -- Banner ccsSPortPrompt DisplayString, -- Login prompt ccsSPortTermType DisplayString, -- terminal type ccsSPortAutomUsr DisplayString, -- automatic user ccsSPortNetMask IpAddress, -- net mask ccsSPortPppMtu Integer32, ccsSPortPppMru Integer32, ccsSPortPppOptions DisplayString, ccsSPortPppFoption DisplayString, ccsSPortModemChat DisplayString, -- initchat send to modem ccsSPortSttyCmd DisplayString, ccsSPortSockTx Integer32, -- socket transmission interval ccsSPortSockPoll Integer32, -- socket polling interval ccsSPortSockIdle Integer32, -- socket idle timeout ccsSPortDBsize Integer32, -- maximum size of the data buffering file ccsSPortDBtime INTEGER, -- data buffering with/without timestamp ccsSPortDBmode DisplayString, -- data bufferinf mode circ or line ccsSPortDBsyslog Integer32, -- size of the data send to syslog ccsSPortDBmenu INTEGER, -- menu of the data buffering ccsSPortDBalarm INTEGER, -- use alarm generating feature ccsSPortSSHbreak DisplayString, -- break sequence (SSH) ccsSPortSniffSess DisplayString, -- sniff session type ccsSPortSniffAdm DisplayString, -- admin users to sniff ccsSPortSniffEsc DisplayString, -- escape char to sniff session ccsSPortSniffMsess DisplayString, -- multiple session ccsSPortTelnetMode INTEGER, -- telnet client mode ccsSPortSysBufSess INTEGER, -- syslog buffering at all times ccsSPortLFSuppress INTEGER, -- LF suppression in socket_server session ccsSPortAutoInput DisplayString, -- Input string to auto answer ccsSPortAutoOutput DisplayString, -- Output string to auto answer ccsSPortPmType DisplayString, -- Power Management IPDU type ccsSPortPmUsers DisplayString, -- Power Management IPDU users ccsSPortPmOutlet DisplayString, -- Power Management Outlets ccsSPortPmKey DisplayString, -- Power Management Hotkey ccsSPortPmNOutlets Integer32, -- Power Management IPDU number of outlets ccsSPortBreakInterval Integer32 -- Break interval (in ms) } ccsSPortNumber OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "number to identifier the serial port. Value 0 is ALL." ::= { ccssportEntry 1 } ccsSPortTty OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) MAX-ACCESS read-write STATUS current DESCRIPTION "The device name for the serial port." ::= { ccssportEntry 2 } ccsSPortName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "Alias name given to the server connected to the serial port." ::= { ccssportEntry 3 } ccsSPortSpeed OBJECT-TYPE SYNTAX INTEGER { s50bps(50), s75bps(75), s110bps(110), s134bps(134), s150bps(150), s200bps(200), s300bps(300), s600bps(600), s1200bps(1200), s1800bps(1800), s2400bps(2400), s4800bps(4800), s9600bps(9600), s14400bps(14400), s19200bps(19200), s28800bps(28800), s38400bps(38400), s57600bps(57600), s115200bps(115200), s230400bps(230400), s460800bps(460800) } MAX-ACCESS read-write STATUS current DESCRIPTION "The speed for serial port." ::= { ccssportEntry 4 } ccsSPortDataSize OBJECT-TYPE SYNTAX Integer32 (4..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The data size for serial port." ::= { ccssportEntry 5 } ccsSPortStopBits OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of stop bits for serial port." ::= { ccssportEntry 6 } ccsSPortParity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..5)) MAX-ACCESS read-write STATUS current DESCRIPTION "The parity for serial port." ::= { ccssportEntry 7 } ccsSPortFlowCtrl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..5)) MAX-ACCESS read-write STATUS current DESCRIPTION "The flow control for serial port." ::= { ccssportEntry 8 } ccsSPortDTRdelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This specifies how long (in miliseconds) a DTR signal will be turned off before it is turned on again." ::= { ccssportEntry 9 } ccsSPortDCDCtrl OBJECT-TYPE SYNTAX INTEGER { notctrl(0), control(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCD signal controls the connection request." ::= { ccssportEntry 10 } ccsSPortLogUtmp OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "CCS update the login records in /var/run/utmp file." ::= { ccssportEntry 11 } ccsSPortLogWtmp OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "CCS update the login records in /var/run/wtmp file." ::= { ccssportEntry 12 } ccsSPortLogform OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the format to write login record." ::= { ccssportEntry 13 } ccsSPortAuthtype OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) MAX-ACCESS read-write STATUS current DESCRIPTION "Authentication type : ." ::= { ccssportEntry 14 } ccsSPortAuthSrv1 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the primary authentication server." ::= { ccssportEntry 15 } ccsSPortAccSrv1 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the primary accounting server." ::= { ccssportEntry 16 } ccsSPortAuthTmo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is the timeout (in seconds) for authentication query to be answered." ::= { ccssportEntry 17 } ccsSPortAuthRetr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This defines the number of times each server is tried before another is contacted." ::= { ccssportEntry 18 } ccsSPortAuthSrv2 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the secondary authentication server." ::= { ccssportEntry 19 } ccsSPortAccSrv2 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of the secondary accounting server." ::= { ccssportEntry 20 } ccsSPortAuthSecret OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the shared secret with authentciation servers." ::= { ccssportEntry 21 } ccsSPortAuthRadP OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "To accept Radius' user without password." ::= { ccssportEntry 22 } ccsSPortAuthAcc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "access restrition on Users." ::= { ccssportEntry 23 } ccsSPortProtocol OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the port serial's protocol." ::= { ccssportEntry 24 } ccsSPortRemoteIP OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the default IP address of the serial port." ::= { ccssportEntry 25 } ccsSPortSocketPort OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) MAX-ACCESS read-write STATUS current DESCRIPTION "This defines an alternative labeling system for the serial port." ::= { ccssportEntry 26 } ccsSPortRemHost OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the host to which the serial port will connect." ::= { ccssportEntry 27 } ccsSPortBanner OBJECT-TYPE SYNTAX DisplayString (SIZE (0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "This defines the banner." ::= { ccssportEntry 28 } ccsSPortPrompt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "This defines the login prompt to the serial port." ::= { ccssportEntry 29 } ccsSPortTermType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "This defines the terminal type." ::= { ccssportEntry 30 } ccsSPortAutomUsr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "This defines the automatic user." ::= { ccssportEntry 31 } ccsSPortNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The network mask used in dial in connection." ::= { ccssportEntry 32 } ccsSPortPppMtu OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The PPP MTU - dial in connection." ::= { ccssportEntry 33 } ccsSPortPppMru OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The PPP MRU - dial in connection." ::= { ccssportEntry 34 } ccsSPortPppOptions OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The PPP options when CCS autodetects the PPP session ." ::= { ccssportEntry 35 } ccsSPortPppFoption OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The PPP forced options when the user has already been authenticated." ::= { ccssportEntry 36 } ccsSPortModemChat OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The initchat send to modem connected." ::= { ccssportEntry 37 } ccsSPortSttyCmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..180)) MAX-ACCESS read-write STATUS current DESCRIPTION "the tty settings after socket connection is established." ::= { ccssportEntry 38 } ccsSPortSockTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the delay (in miliseconds) before transmission to the Ethernet of data received through a serial port ." ::= { ccssportEntry 39 } ccsSPortSockPoll OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Keep-alive timer (miliseconds) to the TCP connection ." ::= { ccssportEntry 40 } ccsSPortSockIdle OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The idle timeout in seconds ." ::= { ccssportEntry 41 } ccsSPortDBsize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum size of the data buffering file." ::= { ccssportEntry 42 } ccsSPortDBtime OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Timestamp in data buffering." ::= { ccssportEntry 43 } ccsSPortDBmode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..5)) MAX-ACCESS read-write STATUS current DESCRIPTION "Data buffering mode : circ or line" ::= { ccssportEntry 44 } ccsSPortDBsyslog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "size of the data buffering send to syslog." ::= { ccssportEntry 45 } ccsSPortDBmenu OBJECT-TYPE SYNTAX INTEGER { displayMenu(0), inactive(1), displayDB(2), displayParc(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Menu of the data buffering." ::= { ccssportEntry 46 } ccsSPortDBalarm OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Generating Alarms." ::= { ccssportEntry 47 } ccsSPortSSHbreak OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "Break sequence - ssh session" ::= { ccssportEntry 48 } ccsSPortSniffSess OBJECT-TYPE SYNTAX DisplayString (SIZE (0..5)) MAX-ACCESS read-write STATUS current DESCRIPTION "Sniff session type" ::= { ccssportEntry 49 } ccsSPortSniffAdm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "List of admin users to sniff session" ::= { ccssportEntry 50 } ccsSPortSniffEsc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) MAX-ACCESS read-write STATUS current DESCRIPTION "Escape sequence used in sniff session" ::= { ccssportEntry 51 } ccsSPortSniffMsess OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Multiple sniff sessions" ::= { ccssportEntry 52 } ccsSPortTelnetMode OBJECT-TYPE SYNTAX INTEGER { text(0), binary(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Mode negotiated by client telnet with the server" ::= { ccssportEntry 53 } ccsSPortSysBufSess OBJECT-TYPE SYNTAX INTEGER { yes(0), no(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Syslog Buffering at all times" ::= { ccssportEntry 54 } ccsSPortLFSuppress OBJECT-TYPE SYNTAX INTEGER { inactive(0), active(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "LF suppression in socket_server session" ::= { ccssportEntry 55 } ccsSPortAutoInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "This string is used to auto answer. It's the input string" ::= { ccssportEntry 56 } ccsSPortAutoOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "This string is used to auto answer. It's the output string" ::= { ccssportEntry 57 } ccsSPortPmType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "IPDU type, when the port protocol is configured as IPDU" ::= { ccssportEntry 58 } ccsSPortPmUsers OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "List of users which can access the IPDU and their respective outlets" ::= { ccssportEntry 59 } ccsSPortPmOutlet OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "List of . pairs, where the server is connected" ::= { ccssportEntry 60 } ccsSPortPmKey OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "Hotkey to grant access to the Power Management from a Telnet/SSH session" ::= { ccssportEntry 61 } ccsSPortPmNOutlets OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of outlets of the IPDU" ::= { ccssportEntry 62 } ccsSPortBreakInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The break interval in miliseconds." ::= { ccssportEntry 63 } END AVOCENT-CYCLADES-CS-INFO-MIB DEFINITIONS ::= BEGIN IMPORTS ccsManagement FROM AVOCENT-CYCLADES-CS-MIB InterfaceIndex FROM IF-MIB MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; ccsInformation MODULE-IDENTITY LAST-UPDATED "200704260000Z" ORGANIZATION "Avocent Corporation" CONTACT-INFO "postal: Avocent Corporation 3541 Gateway Boulevard Fremont, CA 94538, USA e-mail: Technical Support techsupport@avocent.com" DESCRIPTION "This module defines Cyclades CS Family Information objects" REVISION "200704260000Z" DESCRIPTION "First Draft" ::= { ccsManagement 3 } ccsInfoSerialTable OBJECT-TYPE SYNTAX SEQUENCE OF CcsISPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the information of the specific serial port" ::= { ccsInformation 1 } ccsisPortEntry OBJECT-TYPE SYNTAX CcsISPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "One particular serial port " INDEX { ccsISPortNumber } ::= { ccsInfoSerialTable 1 } CcsISPortEntry ::= SEQUENCE { ccsISPortNumber InterfaceIndex, -- X == ttyX sX. ccsISPortTty DisplayString, -- associate device ccsISPortName DisplayString, -- alias name ccsISPortSpeed Integer32, ccsISPortTxBytes Counter32, ccsISPortRXBytes Counter32, ccsISPortErrFrame Counter32, ccsISPortErrParity Counter32, ccsISPortErrBreaks Counter32, ccsISPortErrOverrun Counter32, ccsISPortSigDTR INTEGER, ccsISPortSigCD INTEGER, ccsISPortSigDSR INTEGER, ccsISPortSigRTS INTEGER, ccsISPortSigCTS INTEGER, ccsISPortSigRI INTEGER } ccsISPortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "number to identifier the serial port." ::= { ccsisPortEntry 1 } ccsISPortTty OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The device name for the serial port." ::= { ccsisPortEntry 2 } ccsISPortName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Alias name given to the server connected to the serial port." ::= { ccsisPortEntry 3 } ccsISPortSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The speed for serial port." ::= { ccsisPortEntry 4 } ccsISPortTxBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmited bytes by the serial port." ::= { ccsisPortEntry 5 } ccsISPortRXBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received bytes by the serial port." ::= { ccsisPortEntry 6 } ccsISPortErrFrame OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frame error." ::= { ccsisPortEntry 7 } ccsISPortErrParity OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of parity error." ::= { ccsisPortEntry 8 } ccsISPortErrBreaks OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of breaks error." ::= { ccsisPortEntry 9 } ccsISPortErrOverrun OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of overrun error." ::= { ccsisPortEntry 10 } ccsISPortSigDTR OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of DTR signal." ::= { ccsisPortEntry 11 } ccsISPortSigCD OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of DCD signal." ::= { ccsisPortEntry 12 } ccsISPortSigDSR OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of DSR signal." ::= { ccsisPortEntry 13 } ccsISPortSigRTS OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of RTS signal." ::= { ccsisPortEntry 14 } ccsISPortSigCTS OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of CTS signal." ::= { ccsisPortEntry 15 } ccsISPortSigRI OBJECT-TYPE SYNTAX INTEGER { down(0), up(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state of RI signal." ::= { ccsisPortEntry 16 } END AVOCENT-CYCLADES-CS-ADM-MIB DEFINITIONS ::= BEGIN IMPORTS ccsManagement FROM AVOCENT-CYCLADES-CS-MIB OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI; ccsAdministration MODULE-IDENTITY LAST-UPDATED "200704260000Z" ORGANIZATION "Avocent Corporation" CONTACT-INFO "postal: Avocent Corporation 3541 Gateway Boulevard Fremont, CA 94538, USA e-mail: Technical Support techsupport@avocent.com" DESCRIPTION "This module defines Cyclades CS Family Administration objects" REVISION "200704260000Z" DESCRIPTION "First Draft" ::= { ccsManagement 4 } ccsSave OBJECT-TYPE SYNTAX INTEGER { nosave(0), save(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Exec saveconf command" ::= { ccsAdministration 1 } ccsSerialHUP OBJECT-TYPE SYNTAX INTEGER { norestartportslave(0), restartportslave(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Exec signal_ras hup command" ::= { ccsAdministration 2 } END AVOCENT-CYCLADES-CS-PM-MIB DEFINITIONS ::= BEGIN IMPORTS ccsManagement FROM AVOCENT-CYCLADES-CS-MIB OBJECT-TYPE, MODULE-IDENTITY, Integer32 FROM SNMPv2-SMI InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB DisplayString FROM SNMPv2-TC; ccsPowerManagement MODULE-IDENTITY LAST-UPDATED "200704260000Z" ORGANIZATION "Avocent Corporation" CONTACT-INFO "postal: Avocent Corporation 3541 Gateway Boulevard Fremont, CA 94538, USA e-mail: Technical Support techsupport@avocent.com" DESCRIPTION "This module defines Cyclades CS Family PM Proxy objects" REVISION "200704260000Z" DESCRIPTION "First Draft" ::= { ccsManagement 5 } ccsNumberOfPM OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of PM's connected on the unit" ::= { ccsPowerManagement 1 } ccsPMTable OBJECT-TYPE SYNTAX SEQUENCE OF CcsPMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Allows to read information about each connected PM" ::= { ccsPowerManagement 2 } ccsPMEntry OBJECT-TYPE SYNTAX CcsPMEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about the connected PM" INDEX { ccsPMSerialPortNumber } ::= { ccsPMTable 1 } CcsPMEntry ::= SEQUENCE { ccsPMSerialPortNumber InterfaceIndex, ccsPMNumberOutlets Integer32, ccsPMNumberUnits Integer32, ccsPMCurrent DisplayString, ccsPMVersion DisplayString, ccsPMTemperature DisplayString, ccsPMCommand DisplayString } ccsPMSerialPortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the serial port when the PM is connected." ::= { ccsPMEntry 1 } ccsPMNumberOutlets OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of outlets." ::= { ccsPMEntry 2 } ccsPMNumberUnits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of PM unists that are accessed by this serial port." ::= { ccsPMEntry 3 } ccsPMCurrent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current reading for the PM." ::= { ccsPMEntry 4 } ccsPMVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software version of the PM." ::= { ccsPMEntry 5 } ccsPMTemperature OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The PM temperature." ::= { ccsPMEntry 6 } ccsPMCommand OBJECT-TYPE SYNTAX DisplayString (SIZE (1..100)) MAX-ACCESS read-write STATUS current DESCRIPTION "A character string for the user to send commands to PM. He can use it to does the save command. Or to list the outlets that need to be turned off, or turned on , or cycled or locked or unlocked as a group. The command is the first word and is followed by a space and the outlet list (otulets commands). Valid commands are 'on', 'off', 'cycle', 'lock', 'unlock', 'save'." ::= { ccsPMEntry 7 } ccsPMUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF CcsPMUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Allow operations on specific PM unit connected" ::= { ccsPowerManagement 3 } ccsPMUnitEntry OBJECT-TYPE SYNTAX CcsPMUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Allow operations on outlet" INDEX { ccsPMSerialPortNumber, ccsPMUnitNumber } ::= { ccsPMUnitTable 1 } CcsPMUnitEntry ::= SEQUENCE { ccsPMUnitNumber InterfaceIndex, ccsPMUnitVersion DisplayString, ccsPMUnitOutlets Integer32, ccsPMUnitFirstOutlet Integer32, ccsPMUnitCurrent Integer32, ccsPMUnitMaxCurrent Integer32, ccsPMUnitTemperature Integer32, ccsPMUnitMaxTemperature Integer32 } ccsPMUnitNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of the PM unit in the daisy-chained mode." ::= { ccsPMUnitEntry 1 } ccsPMUnitVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The software version of this PM unit." ::= { ccsPMUnitEntry 2 } ccsPMUnitOutlets OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of outlets of this PM unit." ::= { ccsPMUnitEntry 3 } ccsPMUnitFirstOutlet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the first outlet of this PM unit." ::= { ccsPMUnitEntry 4 } ccsPMUnitCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Current of this PM unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)" ::= { ccsPMUnitEntry 5 } ccsPMUnitMaxCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum current of this PM unit in AMP. The value of this object is the maximum current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the maximum current is 0.5 AMP.)" ::= { ccsPMUnitEntry 6 } ccsPMUnitTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." ::= { ccsPMUnitEntry 7 } ccsPMUnitMaxTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum temperature value of this PM unit in Celsius degrees. The value of this object is the maximum temperature in degrees C * 10. You need to translate the readed value(Ex. : value is 240, the maximum temperature is 24 Celsius). If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." ::= { ccsPMUnitEntry 8 } ccsOutletTable OBJECT-TYPE SYNTAX SEQUENCE OF CcsOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Allow operations on outlet" ::= { ccsPowerManagement 4 } ccsOutletEntry OBJECT-TYPE SYNTAX CcsOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Allow operations on outlet" INDEX { ccsPMSerialPortNumber, ccsOutletNumber } ::= { ccsOutletTable 1 } CcsOutletEntry ::= SEQUENCE { ccsOutletNumber InterfaceIndexOrZero, ccsOutletName DisplayString, ccsOutletServer DisplayString, ccsOutletPower INTEGER, ccsOutletLock INTEGER, ccsOutletPUInterval Integer32 } ccsOutletNumber OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS not-accessible STATUS current DESCRIPTION "The outlet number on the PM. Zero is ALL outlets." ::= { ccsOutletEntry 1 } ccsOutletName OBJECT-TYPE SYNTAX DisplayString (SIZE(1 .. 8)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name given to a particular outlet Maximum size is 8 characters." ::= { ccsOutletEntry 2 } ccsOutletServer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Alias of the Server connected to this outlet ." ::= { ccsOutletEntry 3 } ccsOutletPower OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), cycle (2), unknow (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Getting this object will return the power state of the outlet. Valid return states are UNKNOW, OFF and ON. Setting this object will change the power state of the outlet." ::= { ccsOutletEntry 4 } ccsOutletLock OBJECT-TYPE SYNTAX INTEGER { unlock (0), lock (1), unknow (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Getting this object will return the lock state of the outlet. Setting this object will change the lock state of the outlet." ::= { ccsOutletEntry 5 } ccsOutletPUInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The power unit interval of this outlet in seconds. The value of this object is the actual interval in seconds * 10. You need to translate the readed value (Ex. : value is 5, the interval is 0.5 seconds.)" ::= { ccsOutletEntry 6 } END